ProCheck

Insures Safety - Improves Efficiency
Maintains Comfort - Promotes Customer Satisfaction

 

ProCheck Heating System Precision Tune-up & Safety Inspection

  • Check thermostat operation
  • Check pilot/ignition sequence (adjust pilot or replace thermocouple)
  • Observe main burner operation
  • Check flue draft on natural draft furnaces
  • Test fan switch/heating fan relay operation
  • Check primary limit operation
  • Cycle furnace off and record "fan off" temperature
  • Visually inspect heat exchanger
  • Check blower wheel for cleanliness
  • Check blower motor, if applicable oil bearings, check belt, bearings & pulleys
  • Check air filter (air cleaner and/or replace filters)
  • Check furnace temperature rise
  • Fire furnace and leak check gas line from manual safety shut off valve to main burners
  • Test flue spill switch operation
  • Check auxiliary limit switch operation
  • Test draft safeguard switch operation
  • Perform combustion air test to insure that there is enough ventilation to replace air used for combustion
  • Check humidifier operation
  • Operate the furnace through one complete cycle
  • Clean furnace cabinet

ProCheck Cooling System Precision Tune-up & Safety Inspection

  • Check thermostat operation
  • At Furnace: Inspect filter
  • At Furnace: Inspect blower assembly
  • At Furnace: Inspect and lubricate blower motor
  • At Furnace: Inspect blower assembly
  • At Furnace: Inspect and lubricate blower motor
  • At Furnace: Take amperage reading of blower motor
  • At Furnace: Inspect condensate drain, flush if necessary
  • At Outdoor Unit: Inspect condenser coil
  • At Outdoor Unit: Inspect all electrical connections in condensing unit
  • At Outdoor Unit: Check service valves and service port caps
  • At Outdoor Unit: Check compressor voltage
  • At Outdoor Unit: Check contactor contacts for voltage drop
  • At Outdoor Unit: Read and record compressor discharge gas temp.
  • At Outdoor Unit: Read and record suction line temp.
  • At Outdoor Unit: Read and record liquid line temp.
  • At Furnace: Check evaporator coil performance
  • At Furnace: Check temperature drop across evaporator
  • At Furnace: Check unit operation according to charging calculator
  • At Furnace: Clean furnace cabinet
  • At Furnace: Cycle system through one complete cycle
  • At Furnace: Re-set thermostat
  • Review ProCheck Cooling Performance results with customer
  • Review any appropriate indoor air quality issues with customer
  • Review energy maintenance agreement with customer